SPC FLOORING

With 5 layers as above structure, Sentai 
SPC flooring thickness can be 3.5mm to
10mm with click system. It is waterproof,
anti-scratch, stain-resistant, 25 years

guarantee for residential usage.

 With 5 layers as above structure, Sentai
  SPC flooring thickness can be 3.5mm to
  10mm with click system. It is waterproof,
  anti-scratch, stain-resistant, 25 years
  guarantee for residential usage

EASY TO INSTALL

2G or Drop Down click system is the most popular installation for current SPC core vinyl flooring market.
Stable and durable for any kinds of residential or commercial situations.
    DECIDE YOUR GROUND
          Sentai SPC collection is the perfect choice for heat insulation and sound reduction. All our floor products will provide you a wonderful indoor creativity.
                                    BIG BEVEL 
 
Big Bevel floors feature a larger, more pronounced edge detail, with the individual flooring panels clearly  delineated. A full bevel edge is often combined with a sculpted or hand scraped effect. This combination results in a stunning, time-worn and authentic appearance.
.                                 MICRO BEVEL
 
Micro-Bevel refers to a classof edge styles that have avery small bevel. These are often referred to as eased, kissed, micro-v, and painted micro-bevel. The individual flooring panels are delineated.
 
                                 PAINTED BEVEL
 
These edges exhibit a very fine V-groove on all four
sides of the plank or tile,and the same color UV coating
with the surface. Each painted-bevel has the same
finish as the surface, creating a beautiful plank effect.
The installation of all SENTAI floor is quick and easy. You will have a refreshing andcomfortable living spaces with our durable products. Meanwhile you can create。various design concepts to perfect your own customized flooring combinations.。
Sentai floor can help you to create comfortable working and living environments with  our waterproof Rigid core technology. Such as schools, 
hospitals,restaurants, offices。and any other residential and commercial spaces。

  LIVE HEALTHY

  AND COMFORTABLE

 
     Sentai Floor products don’t contain harmful
     materials and they’re absolute ECO-FRIENDLY.
     We can ensure healthier and warmer flooring
     for everyone who chooses our products with
     Sentai floor special characteristics.
 
  EASY TO CLEAN
  AND MAINTAIN
 
       With the special Rigid Core technology, Sentai Floor can reach
        waterproof, antibacterial and moisture resistant. We can
        ensure you the comfortable living environment.
 
All sentai floor spc collection products provide a better floor for indoor   creativity. Our new spc collection is the perfect choice for better heat  and sound insulation, functional tranquility, and comfort.
SENTAI FLOOR WITH PAD SPC FLOORING
SPC floor stands for stone plastic composite. The main component is lime stone (calcium carbonate),virgin pvc powder, stabilizer and other necessary chemicals.
SENTAI FLOOR WITHOUT PAD SPC FLOORING
 

SPC Installation and Maintenance Instructions
 

Sentai SPC flooring is based on a very unique formulation which combines the advantage ofstone and virgin PVC. Please read this installation guide carefully before installation &maintenance.
Installation tools
Tape measure, Tapping block, Hammer, Pencil, Pry bar or pull bar, Chalk line, Wood or plasticspacers(6-8mm), Crosscut power saw or knife, 3M Blue Tape.

 
Acceptable subflfloor types
Sentai SPC Flooring is a durable and easy to maintain floor covering choice for both residential and commercial applications. Due to its slim & stable structure, it is suitable for both new construction and renovation projects. It can be even installed in lounges and high humidity environments such as bathrooms, kitchens or cellars.

 
Pre-installation subflfloor Requirements
Although Sentai SPC floor is water proof, it is not a moisture barrier. It is still good to make sure concrete is cured and subfloor is dry and structurally sound. Make sure the subfloor is thoroughly swept and free of all debris. And flat level to 0.5cm per 30 square meter.

 
SPC Flooring is suitable for underfloor heating systems using hot water but radiant or electrical underfloor heating is prohibited.
The site where the product to be installed, should be maintained at least 18 °C, and shall notexceed 30°C. If the SPC Flooring itself is stored in a facility within the same range of thetemperatures mentioned above prior to purchasing, no acclimation is required for SPC Flooring itself prior to installation. Room temperatures of 20-22°C and a relative humidity in the range of 35-65% are optimal and
recommended after the installation is completed. With underfloor heating, these values can already be achieved with a surface temperature of 24°C. The humidity should be observed especially in winter seasons and if necessary should be raised to recommended measures.

 
Read before Installation In order to prevent edge damage and prevent bending of Sentai SPC, the boxes should not bestored or carried the narrow sides down, but should only be transported and stored on a flat and stable surface, laid the longer side of the boxes on the floor. In environments without strong and direct sunlight, it is possible to install the flooring without expansion joints up to a 20 meters of length. 
 
For larger areas or more complex layouts such as L-, Z- or U-shape, “hourglass”, constrictions, doorways, and /or if heavy or permanently installed structures obstruct the free movement of the floating installation, the flooring must be split at an appropriate place with an expansion joint.
 
For areas with dynamic horizontal forces, such as those found at gyms, on sports and dance floors, the flooring is not suitable. If any expansion joints present in the screed on the ground, they should be leveled. A 10 mm gap must be left between the SPC floor covering and any other floor covering at transitions, all fixtures, doorframes and walls. If any wood frames or current baseboards present at site, they SPC flooring must be slide underneath by opening a notch to the bottom of said structure. All wedges should be removed and the openings should be covered with suitable trims pieces such as baseboards, transition rails and pipe rosettes.
 
Floating installation requires the floor covering in the doorways to be separated with athreshold. Adjacent surfaces with extreme temperature differences should be separated ifnecessary. Intense and direct sunlight can cause thermal expansion. Suitable shading measuresprevent overheating.
 
The boxes may only be opened immediately before installation. Always mix planks randomlyfrom multiple boxes. Before installation, check the individual element any defects such as color structure, possible physical damage in a good lit environment. No claims on product defect or damage will be accepted post installation. Variances in color,graphic, surface, texture and structure is typical and is not considered a defect. While placing items over the floor with high static pressure load, weight distribution must be done according to the load distribution place.
 
Protection and Maintenance of Your flfloor
Furniture should be moved onto the newly installed floor using an appliance hand truck over hardboard runways.

Oil or petroleum-based products can result in surface staining. Do not track asphalt-driveway sealer or automobile-oil drips onto the SPC floor.

Caster wheeled chairs should have wide, rubber casters. Protective mats are required under office chairs.

Use non-staining mats. Rubber may discolor the floor.

Frequently moved furniture should be equipped with felt pads to avoid scratching the floor.

Heavy furniture and appliances should be equipped with non-staining large surface floor protectors. Furniture with castors or wheels must be easy swiveling, large surface non-staining

and suitable for resilient floors. Do not use ball type castors as they can damage the floor.
Use walk off mats at entrances to prevent dirt and grit from being tracked on to the floor.
 
Installation Type
The SPC flooring is integrated with a sound insulation layer in its construction. The bottom of each plank is fitted with IXPE sound insulation pads, so no additional sound insulation is required and the floor can be installed directly on the ground as a floating system. Floating flooring system is a flooring system that does not require sticking to the bottom layer.
 
Required tools
A ruler, pencil, speed ruler, utility knife or lever cutter, rubber floor hammer, if necessary, punch saw, gasket wedge and a clapper block.
 
Subflfloor Prep / Conditions (DIN 18365 paragraph 3)
The bottom layer must be free of old textile coverings, clean, permanently dry, uniform, firm and stable.
 
Loose, soft or elastic old coverings must be removed. The flatness must conform to line 4 of table 3 of DIN 18202 and shall not exceed 2mm/ m. Any bumps must be removed and the pits filled in.

The following maximum moisture content is applicable to new buildings or floor slabs
For floor heating, the maximum allowable heat output is 55W /m and must be evenly distributed throughout the area.
The surface temperature of the slab shall not exceed 29℃ during heating.
 
Installation Steps
Install the first board with the spring facing the wall. Then, wrap the second piece of wood from the front to the first piece.
 
installation direction 
The final element of the series will be shortened: cut the decorative side with a utility knife, then bend and break the board.
Make sure that the first track is perfectly laid straight and that a distance of 10 mm with the wall wedge is ensured while ensuring that the same allowance is applied to both ends / sides.
 
Following lines:
Offsets between two adjacent lines at both ends must be at least 40cm or 1/2 board length If the rest doesn't fit, simply start it at the beginning of the next line and use the matching New Cut.
Insert the starting section into the long side of the row already in place, gently lock it up and fold. The next element also permeates the long side first and is properly locked when the head ends are folded.
 
installation direction
 
In order to ensure reliable interlocking of profiles, the longitudinal joints must be properly tapped with flapping blocks and rubber hammers.
The elements in the last row were cut to the right size and a 10mm gap was installed with the wall.
 
Finishing touches
All wedges should be removed and baseboards or baseboards, transition rails and piping installed roselike.
 
 
Cleaning and care
Cleaning and caring for SPC flooring is minimal, but critical to the life of your flooring.
Unsuitable detergents, sand, acidic or alkaline substances, solvents, stilettos, metal and metal wear can all attack surfaces and cause scrapes, scratches or discoloration. Furniture must have clean sliders; Office chairs must have suitable soft casters. A suitable floor mat must also be placed under the office chair. Speckles and corrosive substances must be removed from the surface immediately. The use of clean areas greatly reduces the amount of dust
introduced. Clean or vacuum regularly with the nozzles of parquet floors to remove dust and loose dirt.
 
 
E-mail:simon@sentaigroup.com
Mobile phone / WhatsApp:+86 17730471120

ABOUT

Since 2019, we started to develop wood veneer with SPC/Non-PVC floor (abbreviation WS floor). This kind of floor not only has wood veneer as its top layer, but also has SPC/Non-PVC core as its base core.

INFORMATION

CONTACT INFO

  Contact person:Simon ren

  E-mail:simon@sentaigroup.com

   Mobile phone / WhatsApp:+86 17730471120

  Tel:0086-0563-6988013

  Address:NO 23 North jianshe Road,Guangde County ,Anhui Province ,China 242200

SIGN UP FOR OUR NEWSLETTER

If you want, we'll keep you updated on the latest news about products and events

Copyright © 2021 sentaifloor Co., Ltd.  Support by Leadong.